Description
CDI-8
This 8 Channel CDI has been specifically designed for use with MoTeC M1 ECUs. This unit comes with the connector, seals and terminals.
? SPECIFICATIONS
Optimal Operating Voltage: 13 -18 V DC negative ground
Startup Voltage: +6 V
Max. Supply Current: 7.0 A
Power Off Current: < 700 uA
Max Ignition Frequency: 1,200 Hz
Maximum Energy Limit: 750 Hz
Coil Primary Voltage: 480 V
Spark Energy: 115 mJ @ 750 Hz
Trigger: 10 mA falling edge
Ignition Delay: 25 uS
Tacho: 12 V, 100 mA square wave
Maximum Case Temp: 85° C