Performance tuning to win!
Have a question or need some help?

786.264.1706

EMOD016 / ADAPTRONIC MODULAR PLUG-IN ECU - MAZDA MX5 NB8A

This product is one of Adaptonic’s plug-in ECUs, also called eMod016. It’s a direct plug and play for  Mazda MX5 NB8A. Our main objective in creating the Adaptr
In Stock


This product is one of Adaptonic’s plug-in ECUs, also called eMod016. It’s a direct plug and play for  Mazda MX5 NB8A.

Our main objective in creating the Adaptronic Modular ECU line is to work towards Adaptronic’s mission which is to give people control. In doing this, we came up with a system which would give people greater flexibility and at the same time, overcome the limitations of our main product line, the Select ECUs.

 

WHAT'S IN THE BOX?

 

    • Engine control unit
    • USB (tuning) cable
    • 1GB USB Stick
    • Adaptronic stickers

 

GENERAL FEATURES

 

  • Modular system, so that people can buy hardware upgrades later as their needs develop (eg additional inputs, outputs, or specific functions, eg drive by wire or built-in lambda)
  • Wireless communication
  • Fast USB communication, requiring no drivers
  • Headphone port for listening to the knock sensor while tuning
  • 4 x serial ports
  • 1 x CAN port
  • Power over USB to do loading of maps, firmware etc without having to provide it with 12V power
  • 32MB of onboard logging to flash
  • Exception logging, able to detect faults and log a bunch of things that happen around the same time to help with ECU setup and tech support
  • Bigger maps, more of them, and more dedicated maps.
  • Tested to MIL-STD-202G, a military vibration standard, which varies the frequency and peaks at 7.5g of oscillating acceleration

FEATURES / SPECIFICATIONS

Control board

VariableNumberDetails
Analogue 0-5V inputs11Each is 0 – 5.5V, 55k input impedance

 

  • 2 x TPS / pedal position
  • 6 x pressure – Oil, Fuel, Internal intake MAP, internal exhaust MAP, external intake MAP, external exhaust MAP
  • 3 x spare for servo feedback / external inputs
Analogue oxygen sensor inputs2Each can be either:

 

  • 0 – 5.5V, 55k input impedance
  • 0- 3.3V, 1M input impedance
Temperature inputs4Each is 0 – 5.5V, 55k input impedance to ground
Each can be:

 

  • Non-biased, eg in piggyback mode. Calibration is in mV
  • Biased, calibration is in Ohms. 3 internal pull-ups, 1k5, 2k2, 4k7, automatically selected by the ECU

Manifold air temperature, coolant temperature, oil temperature, fuel temperature

Crank trigger inputs3
  • Selectable 2k2 pullup (on in digital mode, off in reluctor mode)
  • Variable voltage trigger threshold from 0 to 65V – either arm input for reluctor or threshold for digital input
  • AC coupled zero crossing trigger in reluctor mode
  • Variable filtering 1 to 192 µs
  • See built-in scope section
Vehicle speed input1
  • Selectable 2k2 pullup
  • Variable voltage trigger threshold from 0 to 65V
  • Variable filtering 1 to 192 µs
  • See built-in scope section
Sensor power and ground
  • 5V regulated output for sensors, max 100 mA, current limited (voltage is monitored by ECU)
  • Sensor ground connected to ground inside ECU under firmware control to detect external ground loops in the wiring (voltage is monitored by ECU)
Knock input1
  • 50 k input impedance
  • Sampled at 80 kHz (12-bit resolution, 3.3V peak to peak max voltage),
  • Variable second order highpass and lowpass filters
  • Selectable start and end of sampling windows (in crank angle)
Wired Outputs2
  • Dedicated outputs for tacho and EFI relay
  • Tacho output has inductor to generate back-EMF spike for impulse tachometers.
  • EFI relay output can be configured as fuel pump or EFI relay. Switches to ground, current limited to 600 mA
Headphone output1Mono output, can be selected as direct knock input or filtered knock input
Power sources3ECU can be powered by 12V EFI input, ignition switch, or USB (USB for settings / firmware upgrades / log retrieval only; 12V must be applied to read inputs)
CAN channel1
  • Up to 1 Mbps
  • Internal 120 Ohm terminating resistor can be turned on and off with ECU setting on each channel
USB connection1
  • Standard USB mini AB connector.
  • 12 Mbps max speed
  • USB appears as mass storage device (USB stick); no drivers are necessary
  • Software installer included on mass storage device
Serial connections4
  • All 4 use 4-pin Molex connectors
  • 2 x serial in (ground, transmit, receive)
  • 1 x serial out (ground, transmit, receive)
  • 1 x controller out (ground, transmit, receive and 12V switched, current limited power) – eg for dash, hand controller
Wireless connection1
  • Access point
  • 230kbps max speed
  • Settings and live data only (no log retrieval due to speed)
Inbuilt sensors
  • Microphone
  • 3 axis accelerometer
  • 3 axis rate gyro
Inbuilt logging32 MB
  • Max 30 hrs @ 10 Hz, 13 channels
  • Min 20 mins @ 100 Hz, 125 channels
Exception (fault) detection16 MBSeparate logging memory for storing logs during “exceptions” (sensor / trigger faults etc)
Built-in scope4 channels
  • Max sample rate 200 kHz (5µs sample period)
  • 1000 samples per screen (min 5ms across the screen)
  • Analogue trigger inputs sampled at 40 kHz

Channels include

  • Analogue CAS inputs
  • Peak detected CAS voltages
  • CAS threshold voltages
  • Filtered CAS inputs
  • Analogue external inputs
  • Raw and filtered knock waveforms
  • Current engine angle
  • Calibrated input values
  • Intermediate calculation values
  • Output calculated values
Main loop execution speedVariable depending on tuning mode and corrections enabled, 400 Hz nominal

 

Number of injector outputs8
  • Switching topology for low heating
  • Peak and hold current waveforms
  • Programmable peak and hold current
  • Max current per channel 4A continuous
  • Nominal current per channel 1A (can be controlled in software)
  • Unused injector outputs can be configured as auxiliary outputs, PWM capable, but only switching to ground
  • Output voltage and current monitored
Number of ignition outputs8
  • Appears as a 470 Ohm to supply when high, short to ground when low
  • Current limited output
  • Unused injector outputs can be configured as auxiliary outputs, PWM capable, but only switching to ground, and only low current
  • Voltage and current monitored
Number of aux outputs4
  • Push-pull outputs (can drive high or low)
  • High side current limited to 1.2A
  • Low side current up to 4A continuous
  • Can be PWM but not engine synchronous
  • Voltage and current monitored
Hardware upgrades2
  • Small Modules ( analogue input, real – time input, drive – by – wire control and output module)